INSTRUCTION MANUAL
The connection of the dimmer is achieved through a single-phase supply by a Schuko plug.
It is a 6 channel dimmer that works digitally. The DMX connection is on the front panel with a male input XLR 3 PIN (1st PIN ground – the 2nd PIN (-) and the 3rd PIN (+) ), further DMX connection is achieved by a female XLR. You can connect the DMX to the terminal strips at the back of the dimmer.
The red led indicator shows the voltage supply and the green led indicator shows the communication DMX (DATA).
The display indicates the number of channels DMX (001-512). The buttons UP / DOWN increase or decrease the number of the channels (e.g. 001, 002, 003, 004…).
The load is connected to the output with 3 PIN terminal strips. The signs are L for the (phase), N for the (neutral) and G for the (ground) and the electric power of each channel is 400 W.
After connecting the dimmer to thew power turn it on using the switch ON-OFF. The red LED is on and the display shows error (ie. There is no communication). To start the communication with the dimmer connect the DMX cable to the console. The display shows 001 and the LED DATA is on. The channel shows on the display is the starting channel.
If the dimmer display indicates 001 the connected channels are 1-6. If it shows 002 he channels 2-7. If it shows 003 the channels 3-8 are connected and so on.
If you want to connect multiple dimmers to the DMX OUT plug connect your next dimmer to the In – Out terminal strips at the back of the panel.
If any led does not light up it means that there is an error at the connection.
To activate the manual check mode hold pressed the buttons (+ ) and ( -) simultaneously for 3 sec. Then the display indicates <1.0.0> . You can choose the preferred channel with the buttons (+ / -) and the preferred lighting percentage with the UP/DOW buttons. At the <7.0.0> address you can control all the channels together (master mode).
To exit the manual check mode pressed the buttons (+ / -) simultaneously.
Minimum control load 3 W.